logo
 



CCTV Surveillance Power Supply Series
  CCTV Power Supply
  PTC CCTV Power Supply
  weatherproof power box
Plastic Shell Power Supply
  Desktop
  Adapter
Switch Power Supply
  single output (S series)
  HSP Series (PFC)
  HS Series (Compact)
  two groups output
  three groups output
  four groups output
LED Electrical Driver
  waterproof LED Driver-V
  waterproof LED Driver-A
  weatherproof LED power
mulview contact us
Mulview CCTV-FAQ

web www.mtlcctv.com
power supply alibaba
 
 
power supply FAQ
Power Supply
11. For certain need, is it possible to reduce the noise of fan?

Ans:
Noise is directly related to the fan which is build into the power supply. Lowering the airflow of the fan means reducing the heat dissipation ability. It will also influence the reliability of the products. Furthermore, minimum airflow
of fans is defined by Safety Organization and a safety appendage will be needed if using a new fan. Generally, when we choose a suitable power supply, fan is not necessary if wattage is under 150W. Between 150~500W, both fan and fanless products are available. Above 500W, a fan is needed.

12. What should be noticed when installing a power supply in vertical and horizontal directions?

Ans:
Most small wattage and fanless power supplies are mainly installed in the horizontal position. If you have to install it vertically because of mechanical limitation, you should consider the output derating due to the heat concern. The temperature derating curve can be found on the spec sheet. Regarding the power supplies with built-in fan or the application has forced cooling system, vertical and horizontal installations have less difference.

13. Why the fan is not running after turning on certain models?

Ans:
Some models control the fan based on internal temperature to extend its life time. For example, the Fan ON temperature for the S-240 series is ≧ 40C (RT1). If the internal temperature does not reach the preset value, the fan will remain still until receiving the start up signal.

14. What is “Inrush Current”? What will we notice?

Ans:
At input side, there will be (1/2 ~1 cycle, ex. 1/120 ~ 1/60 seconds for 60 Hz AC source) large pulse current (20~60A based on the design of S.P.S.) at the moment of power on and then back to normal rating. This “Inrush Current” will appear every time you turn on the power. Although it will not damage the power supply, we suggest not turning the power supply ON/OFF very quickly within a short time. Besides, if there are several power supplies turning on at the same time, the dispatching system of AC source may shut off and go into protection mode because of the huge inrush current. It is suggested that these power supplies start up one by one or use the remote control function of S.P.S. to turn them on/off.

15. What is PFC?

Ans:
PFC stands for Power Factor Correction. The purpose of PFC is to improve the
ratio of apparent power and real power. The power factor is only 0.4~0.6 in non-PFC models. In PFC models, the power factor can reach above 0.95. The calculation formulas are as below:

Apparent Power=Input Voltage x Input Current (VA)
Real Power= Input Voltage x Input Current x Power Factor (W)

From the environment friendly point, the electric power plant needs to generate a power which is higher than apparent power in order to steadily provide electricity to the market. The real usage of electricity should be defined
by real power. Assuming the power factor is 0.5, the power plant needs to produce more than 2VA to satisfy 1W real
power. On the contrary, if the power factor is 0.95, the power plant only needs to generate more than 1.06VA to
provide 1W real power need. It will be more effective.

<< Previous Page          Next Page >>

 

 
   
FAQ|Link|Sitemap|Privacy Policy|Legal Notice|Set Homepage | Add to favorite


Copyright©Mulview Technology(ShenZhen) Co.,Limited All Rights Reserve
TEL:0086-755-88849659  E-mail:sales@mtlcctv.com       mulviewcctv@gmail.com