Model
Specification |
CH1 |
CH2 |
CH1 |
CH2 |
| DC output voltage |
5V |
12V |
-5V |
-12V |
| Output voltage error(Note:2) |
±2% |
±6% |
±5% |
±5% |
| Rated output current |
5.5A |
2A |
0.5A |
0.5A |
| Output current rage |
0.5-8A |
0.1-3A |
0-1A |
0-1A |
| Wave and noise(Note :3) |
100mVp-p |
120mVp-p |
100mVp-p |
120mVp-p |
| Inlet stability(Note :4) |
±0.5% |
±1% |
±0.5% |
±0.5% |
| Load stablity (Note :5) |
±0.5% |
±4% |
|
|
| DC output power |
60W |
| Efficiency |
70% |
| Adjustable range for DC voltage |
CH1:+10,-5% |
| AC input voltage range |
85-132VAC/170-264VACSelected by
switch47-63Hz;120-370VDC |
| Input current |
1.3A/115V 0.8A/230A |
| AC INnrush current |
Cold-start current 18A/115V 36A/230V |
| Leakage current |
<1mA/240VAC |
| Overload proctection |
105%-150%Type:Foldback:current limiting reset:auto
recovery |
| Over-voltage protection |
CH:5.75-6.75V |
| High-temperature protection |
………… |
| Temperature coefficient |
±0.03%/℃(0-50℃)ON+5V |
| Setup rise hold up time |
800ms,50ms,10ms/115VAC
300ms,50ms,80ms/230VAC |
| Vibration |
10-500Hz,2G 10min,/1cycle,Period for60min,Each axes |
| Withstand voltage |
Input and output internal:1.5KVAC,Input and
enclosure:1.5KVAC,Output and enclosure:0.5KVAC |
| Isolation resistance |
Input and output internal:Input and enclosure,Output
and enclosure:500VDC/100MΩ |
| Working temperature and humidity |
-10℃~+60℃(Refer to output derating curve),20%~90%RH |
| Store temperature and humidity |
-20℃~+85℃,10%~95%RH |
| Overall dimension |
159×97×38mm |
| Weight |
0.55Kgs |
| Safety standards |
UL1950 Approved |
| EMC standards |
CISPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification |
Note:
1.The testing condition for the paramenter
above is :230VAC input,rated load,25℃70% RH.Humidity.
2.Error.include the setting error,line stability and load
stability.(Note:5).
3.Wave test:adopting "A12"double wire for
20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest
voltage of inlet is up to the highest voltage.
5.Load stability
test:the load is from 0% to 100%.
6.Total output canbe maximum
Current,total load can not exceed the maximum output power.
7.C2、3、6 must be knocked down. |